Gas Fired InfraRed Heaters

MODULATING UNITARY RANGE (VA)

<< Back  

MODULATING UNITARY RANGE (VA)
Click on Image(s) Below to Enlarge
MODULATING UNITARY RANGE (VA)MODULATING UNITARY RANGE (VA)MODULATING UNITARY RANGE (VA)
MODULATING UNITARY RANGE (VA)MODULATING UNITARY RANGE (VA)MODULATING UNITARY RANGE (VA)
MODULATING UNITARY RANGE (VA)MODULATING UNITARY RANGE (VA)MODULATING UNITARY RANGE (VA)
MODULATING UNITARY RANGE (VA)MODULATING UNITARY RANGE (VA)

Advanced Radiant Systems? unitary flagship is the Modulating Unitary Range (VA). The VA Range boasts the highest turndown ratio in the industry on a unitary heater. Unlike other manufacturers? units, the VA Range modulates both fuel and air simultaneously for a true modulation benefit. By meeting building envelop heating demands on an ongoing basis, energy consumption is minimized. Occupant comfort is also enhanced by offering a more consistent temperature output than found with single and dual stage heaters. These units are exceptionally suited for those areas in a facility with inconsistent heating demands. 

ADAPTIVE TECHNOLOGY

The VA Range automatically adjusts air and gas to properly regulate the temperature in a given space. The direct analog signal and effective and non-proprietary controls make operation simple. The VA is not preprogrammed; it reads the room and adjusts itself accordingly. Therefore, the output of energy will be a steady stream; eliminating temperatures dips and rises. This improves thermal efficiencies in excess
of 80%.

FEATURES

  • Rates 48,000 to 200,000 BTU/HR
  • Fully modulates gas and air
  • Modulating differential 40%, largest in the industry
  • Fully automatic or manual control of burner modulation
  • Self-regulating, no fixed points (adapts to the demand regardless of conditions)
  • Simple, effective controls
  • Reliable ? pressure measured mechanically
  • Outdoor option
  • Self-diagnostic ignition module
SKU: VA
Request a Quote

STANDARD EQUIPMENT

  • Burner housing assembly
  • Heat treated aluminized tubing with gasket
  • Combustion air inlet collar
  • Turbulators when required
  • All tubes, reflectors, couplings, end caps and hanging accessories per specified length

OPTIONAL EQUIPMENT

  • U or L bends for specific layouts
  • Energy efficient side reflectors and lower shields
  • Vent terminal, fresh air inlet hood
  • Stainless steel or Silkote tubing
  • Various control options
  • Outdoor vent kit

CONTROL OPTIONS

  • Modulating thermostat
  • Building Management System capability
  • Potentiometer
  • Remote indoor sensor
  • Multiple units on one control system

VA Dimensions